1.Transient introduction
YR,YRKK,YRKS, JR, JR2 Sequence Substantial Voltage Slip Ring A few Period Asynchronous Induction AC Motor are developed with the application of contemporary engineering resulting in compact machines featuring outstanding dynamic qualities, meeting the most severe application in locations that include automation and approach control.
Besides providing dependability and higher overall performance, which will assure extended functioning intervals CZPT necessitating any routine maintenance, YR,YRKK,YRKS substantial voltage AC motors current excellent running attributes, which consist of:
(1)Wide velocity variation assortment
(two)Dimensions as for each GB and IEC CZPTs
(3)Higher effectiveness
(4)Reduced sound amount
(five)Substantial second of inertia
(six)Large ability to dynamic hundreds
(seven)Rugged design
(eight)Higher vibration resistance
(9)Superb commutation high quality
two.CZPT Functions
(one)3-section, fifty, sixty Hz
(two)Voltage: 380 to 11000 V
(three)Rated output: up to 12500kw
(4)Number of poles: 2 ,four,six,eight,10 or 12poles
(five)Frame sizes: 450 mm to 630mm
(6)Wound rotor Slip ring
(7)Diploma of safety: IP23 to IP54,Completely enclosed
(8)Course insulation F with course 120ºC temperature increase
(nine)Grease nipples for frame 450 to 630MM
(ten)Continuous Responsibility S1
(eleven)With thermal safety PTC140 ºC or PT100
(twelve)Bigger diameter shafts for the highest overhung load ratings in the market
(13)Oversized roller bearings for maximum load potential
(fourteen)Other optional functions beneath request
3.Standard purposes
(one)Compressor
(two)Rubber mixer
(3)Enthusiasts and Pumps
(4)Air brower
(5)Coal mill and rolling mill
(six)Crushers
(7)CZPT belts
(8)Centrifugal devices
(9)Lathe
(10)CZPT
4.CZPT parameters:
Comparison of different series 6 Kv, ten Kv, eleven Kv High Voltage CZPT motors
No. | Squirrel-cage motor | Y | YKK | YKS | Y2 YJS |
Slip-ring motor | YR | YRKK | YRKS | / | |
one | Construction | Box-kind development, manufactured up of steel plates welded with each and every other | Compact struction | ||
two | Cooling strategy | IC01 or (IC11, IC21, IC31) | IC611 or IC616 | IC81W | IC411 |
3 | Organic air flow, with prime mounted defense include | With top mounted air-air cooler | With leading mounted air-h2o cooler | ||
4 | Security type | IP23 | IP44, IP54, IP55 | IP44, IP54 IP55 | IP54 IP55 |
5 | Insulation | F | |||
6 | Mounting arrangement | IMB3, IMV1, IMB35 | |||
7 | Voltage CZPT | 380~690V, 2400V 4160V, 3kv, 3.3kv 6kv, six.6kv 10kv, 11kv | |||
eight | Frequency CZPT | 50Hz , 60Hz |